Type | Index number | Status |
---|---|---|
Centralised MEV and MVHR systems | 500066 | Normal |
Brand | Model name | Model qualifier |
Paul | Atmos 175 DC | |
System type | balanced whole-house mechanical ventilation with heat recovery | |
Duct type | rigid | |
Minimum duct size | 125 mm diameter or 204 x 60 rectangular or larger | |
Original manufacturer name | Paul Waermerueckgewinnung Gmbh | |
Current manufacturer name | Paul Waermerueckgewinnung Gmbh | |
Manufacturer address |
Vettermannstr. 1-5 D-08132 Muelsen Germany |
|
Manufacturer phone | 01484 461705 | |
Manufacturer website | www.paulventilation.co.uk | |
First year of manufacture | 2006 | |
Final year of manufacture | 2008 | |
Summer bypass | no | |
Integrated to exhaust air heat pump | No | |
Entry updated | 18/05/2016 18:30 |
K+n wet rooms | SFP (W/l/s) [2009] | Efficiency (%) [2009] | SFP (W/l/s) [2012] | Efficiency (%) [2012] | SFP (W/l/s) [10] | Efficiency (%) [10] |
---|---|---|---|---|---|---|
n = 1 | 0.69 | 86% | 0.55 | 86% | 0.55 | 86% |
n = 2 | 0.50 | 86% | 0.53 | 86% | 0.53 | 86% |
n = 3 | 0.51 | 86% | 0.61 | 86% | 0.61 | 86% |
n = 4 | 0.55 | 86% | 0.73 | 87% | 0.73 | 87% |
n = 5 | 0.62 | 87% | 0.88 | 87% | 0.88 | 87% |
n = 6 | 0.70 | 87% | 1.04 | 88% | 1.04 | 88% |
n = 7 | 0.81 | 87% | - | - | - | - |
Back to search results | Back to search | Back to all product types