Type | Index number | Status |
---|---|---|
Centralised MEV and MVHR systems | 500068 | Normal |
Brand | Model name | Model qualifier |
Paul | Thermos 300 DC | |
System type | balanced whole-house mechanical ventilation with heat recovery | |
Duct type | rigid | |
Minimum duct size | 125 mm diameter or 204 x 60 rectangular or larger | |
Original manufacturer name | Paul Waermerueckgewinnung Gmbh | |
Current manufacturer name | Paul Waermerueckgewinnung Gmbh | |
Manufacturer address |
Vettermannstr. 1-5 D-08132 Muelsen Germany |
|
Manufacturer phone | 01484 461705 | |
Manufacturer website | www.paulventilation.co.uk | |
First year of manufacture | 2006 | |
Final year of manufacture | 2012 | |
Summer bypass | no | |
Integrated to exhaust air heat pump | No | |
Entry updated | 18/05/2016 18:30 |
K+n wet rooms | SFP (W/l/s) [2009] | Efficiency (%) [2009] | SFP (W/l/s) [2012] | Efficiency (%) [2012] | SFP (W/l/s) [10] | Efficiency (%) [10] |
---|---|---|---|---|---|---|
n = 1 | 0.53 | 91% | 0.49 | 91% | 0.49 | 91% |
n = 2 | 0.50 | 91% | 0.53 | 91% | 0.53 | 91% |
n = 3 | 0.50 | 91% | 0.62 | 90% | 0.62 | 90% |
n = 4 | 0.54 | 90% | 0.75 | 89% | 0.75 | 89% |
n = 5 | 0.62 | 89% | 0.90 | 89% | 0.90 | 89% |
n = 6 | 0.72 | 89% | 1.05 | 88% | 1.05 | 88% |
n = 7 | 0.83 | 89% | - | - | - | - |