Type | Index number | Status |
---|---|---|
Centralised MEV and MVHR systems | 500215 | Normal |
Brand | Model name | Model qualifier |
Paul | Focus F200 | |
System type | balanced whole-house mechanical ventilation with heat recovery | |
Duct type | rigid | |
Minimum duct size | 125 mm diameter or 204 x 60 rectangular or larger | |
Original manufacturer name | Paul Waermerueckgewinnung Gmbh | |
Current manufacturer name | Paul Waermerueckgewinnung Gmbh | |
Manufacturer address |
Vettermannstr. 1-5 D-08132 Muelsen Germany |
|
Manufacturer phone | 01484 461705 | |
Manufacturer website | www.paulventilation.co.uk | |
First year of manufacture | 2010 | |
Final year of manufacture | current | |
Summer bypass | no | |
Integrated to exhaust air heat pump | No | |
Entry updated | 11/11/2015 10:34 |
K+n wet rooms | SFP (W/l/s) [2009] | Efficiency (%) [2009] | SFP (W/l/s) [2012] | Efficiency (%) [2012] | SFP (W/l/s) [10] | Efficiency (%) [10] |
---|---|---|---|---|---|---|
n = 1 | 0.91 | 94% | 0.82 | 94% | 0.82 | 94% |
n = 2 | 0.76 | 94% | 0.92 | 94% | 0.92 | 94% |
n = 3 | 0.87 | 95% | 1.14 | 93% | 1.14 | 93% |
n = 4 | 0.98 | 94% | 1.40 | 91% | 1.40 | 91% |
n = 5 | 1.15 | 93% | - | - | - | - |
Back to search results | Back to search | Back to all product types