Type Index number Status
Centralised MEV and MVHR systems 500268 Normal
Brand Model name Model qualifier
Pichler 08 LG 250
     
System type balanced whole-house mechanical ventilation with heat recovery
Duct type rigid  
Minimum duct size 125 mm diameter or 204 x 60 rectangular or larger
Original manufacturer name J Pichler GmbH
Current manufacturer name J Pichler GmbH
Manufacturer address Postfach 32
Karlweg 5
A-9021 Klagenfurt
Austria
Manufacturer phone +43 463 32769
Manufacturer website www.pichlerluft.at
First year of manufacture 2010  
Final year of manufacture current  
Summer bypass yes  
Integrated to exhaust air heat pump No  
Entry updated 25/11/2013 09:40  

 

K+n wet rooms SFP (W/l/s) [2009] Efficiency (%) [2009] SFP (W/l/s) [2012] Efficiency (%) [2012] SFP (W/l/s) [10] Efficiency (%) [10]
n = 1 0.81 88% 0.69 88% 0.69 88%
n = 2 0.64 88% 0.67 88% 0.67 88%
n = 3 0.65 88% 0.73 88% 0.73 88%
n = 4 0.67 88% 0.84 87% 0.84 87%
n = 5 0.73 87% 0.96 86% 0.96 86%
n = 6 0.80 88% 1.09 85% 1.09 85%
n = 7 0.89 86% - - - -

 