Type Index number Status
Centralised MEV and MVHR systems 500294 Normal
Brand Model name Model qualifier
Dantherm HCV 5
     
System type balanced whole-house mechanical ventilation with heat recovery
Duct type rigid  
Minimum duct size 125 mm diameter or 204 x 60 rectangular or larger
Original manufacturer name Dantherm Air Handling A/S
Current manufacturer name Dantherm Air Handling A/S
Manufacturer address Marienlystvej 65
DK-7800 Skive
Denmark
Manufacturer phone +45 96 14 37 00
Manufacturer website www.dantherm.com
First year of manufacture 2010  
Final year of manufacture current  
Summer bypass no  
Integrated to exhaust air heat pump No  
Entry updated 11/11/2015 10:34  

 

K+n wet rooms SFP (W/l/s) [2009] Efficiency (%) [2009] SFP (W/l/s) [2012] Efficiency (%) [2012] SFP (W/l/s) [10] Efficiency (%) [10]
n = 2 0.64 82% 0.64 82% 0.64 82%
n = 3 0.62 82% 0.72 82% 0.72 82%
n = 4 0.65 82% 0.85 83% 0.85 83%
n = 5 0.71 83% 1.01 84% 1.01 84%
n = 6 0.82 83% - - - -

 