Type | Index number | Status |
---|---|---|
Centralised MEV and MVHR systems | 500699 | Normal |
Brand | Model name | Model qualifier |
Pichler | 08LG350V | |
System type | balanced whole-house mechanical ventilation with heat recovery | |
Duct type | rigid | |
Minimum duct size | 125 mm diameter or 204 x 60 rectangular or larger | |
Original manufacturer name | J Pichler GmbH | |
Current manufacturer name | J Pichler GmbH | |
Manufacturer address |
Postfach 32 Karlweg 5 A-9021 Klagenfurt Austria |
|
Manufacturer phone | +43 463 32769 | |
Manufacturer website | www.pichlerluft.at | |
First year of manufacture | 2018 | |
Final year of manufacture | current | |
Summer bypass | yes | |
Integrated to exhaust air heat pump | No | |
Entry updated | 26/04/2021 08:53 |
K+n wet rooms | SFP (W/l/s) [2009] | Efficiency (%) [2009] | SFP (W/l/s) [2012] | Efficiency (%) [2012] | SFP (W/l/s) [10] | Efficiency (%) [10] |
---|---|---|---|---|---|---|
n = 1 | 0.75 | 95% | 0.65 | 95% | 0.65 | 95% |
n = 2 | 0.61 | 95% | 0.60 | 94% | 0.60 | 94% |
n = 3 | 0.55 | 94% | 0.62 | 93% | 0.62 | 93% |
n = 4 | 0.59 | 94% | 0.70 | 93% | 0.70 | 93% |
n = 5 | 0.61 | 93% | 0.76 | 92% | 0.76 | 92% |
n = 6 | 0.68 | 93% | 0.90 | 91% | 0.90 | 91% |
n = 7 | 0.75 | 92% | 1.06 | 90% | 1.06 | 90% |
Back to search results | Back to search | Back to all product types