Type | Index number | Status |
---|---|---|
Centralised MEV and MVHR systems | 500326 | Normal |
Brand | Model name | Model qualifier |
Emmeti | RECUPERA-MED-ER02511-EC | |
System type | balanced whole-house mechanical ventilation with heat recovery | |
Duct type | rigid | |
Minimum duct size | 125 mm diameter or 204 x 60 rectangular or larger | |
Original manufacturer name | Emmeti SpA | |
Current manufacturer name | Emmeti SpA | |
Manufacturer address |
Via Brigata Osoppo 166 33074 Fontanafredda (PN) Italy |
|
Manufacturer phone | +39 0434 567911 | |
Manufacturer website | www.emmeti.com | |
First year of manufacture | 2010 | |
Final year of manufacture | current | |
Summer bypass | no | |
Integrated to exhaust air heat pump | No | |
Entry updated | 11/11/2015 10:34 |
K+n wet rooms | SFP (W/l/s) [2009] | Efficiency (%) [2009] | SFP (W/l/s) [2012] | Efficiency (%) [2012] | SFP (W/l/s) [10] | Efficiency (%) [10] |
---|---|---|---|---|---|---|
n = 1 | 0.62 | 93% | 0.61 | 93% | 0.61 | 93% |
n = 2 | 0.60 | 93% | 0.69 | 93% | 0.69 | 93% |
n = 3 | 0.64 | 92% | 0.84 | 91% | 0.84 | 91% |
n = 4 | 0.74 | 91% | 1.01 | 90% | 1.01 | 90% |
n = 5 | 0.83 | 90% | 1.20 | 89% | 1.20 | 89% |
n = 6 | 0.98 | 90% | - | - | - | - |
Back to search results | Back to search | Back to all product types