Type | Index number | Status |
---|---|---|
Centralised MEV and MVHR systems | 500507 | Normal |
Brand | Model name | Model qualifier |
Aermec | RePuro 550 | |
System type | balanced whole-house mechanical ventilation with heat recovery | |
Duct type | rigid | |
Minimum duct size | 125 mm diameter or 204 x 60 rectangular or larger | |
Original manufacturer name | Aermec SpA | |
Current manufacturer name | Aermec SpA | |
Manufacturer address |
Via Roma 996 Bevilacqua Verona 37040 Italy |
|
Manufacturer phone | +39 0442 633111 | |
Manufacturer website | www.aermec.com | |
First year of manufacture | 2012 | |
Final year of manufacture | current | |
Summer bypass | no | |
Integrated to exhaust air heat pump | No | |
Entry updated | 20/03/2017 14:19 |
K+n wet rooms | SFP (W/l/s) [2009] | Efficiency (%) [2009] | SFP (W/l/s) [2012] | Efficiency (%) [2012] | SFP (W/l/s) [10] | Efficiency (%) [10] |
---|---|---|---|---|---|---|
n = 1 | 1.10 | 90% | 0.83 | 90% | 0.83 | 90% |
n = 2 | 0.82 | 90% | 0.78 | 90% | 0.78 | 90% |
n = 3 | 0.73 | 90% | 0.82 | 89% | 0.82 | 89% |
n = 4 | 0.74 | 89% | 0.91 | 88% | 0.91 | 88% |
n = 5 | 0.80 | 89% | 1.07 | 88% | 1.07 | 88% |
n = 6 | 0.89 | 88% | 1.24 | 87% | 1.24 | 87% |
n = 7 | 0.99 | 88% | 1.44 | 87% | 1.44 | 87% |
Back to search results | Back to search | Back to all product types