Type | Index number | Status |
---|---|---|
Centralised MEV and MVHR systems | 500702 | Normal |
Brand | Model name | Model qualifier |
Flakt Group | EIS-230 | |
System type | balanced whole-house mechanical ventilation with heat recovery | |
Duct type | rigid | |
Minimum duct size | 125 mm diameter or 204 x 60 rectangular or larger | |
Original manufacturer name | Vectaire | |
Current manufacturer name | Flakt Group UK Ltd | |
Manufacturer address |
Dolphin House Moreton Business Park Hereford HR48DS |
|
Manufacturer phone | 07764472115 | |
Manufacturer website | www.flaktgroup.com | |
First year of manufacture | 2017 | |
Final year of manufacture | current | |
Summer bypass | partial | |
Integrated to exhaust air heat pump | Yes | |
Entry updated | 26/04/2021 12:16 |
K+n wet rooms | SFP (W/l/s) [2009] | Efficiency (%) [2009] | SFP (W/l/s) [2012] | Efficiency (%) [2012] | SFP (W/l/s) [10] | Efficiency (%) [10] |
---|---|---|---|---|---|---|
n = 1 | 0.75 | 89% | 0.56 | 89% | 0.56 | 89% |
n = 2 | 0.56 | 89% | 0.47 | 89% | 0.47 | 89% |
n = 3 | 0.46 | 89% | 0.50 | 88% | 0.50 | 88% |
n = 4 | 0.46 | 88% | 0.56 | 87% | 0.56 | 87% |
n = 5 | 0.49 | 88% | 0.66 | 86% | 0.66 | 86% |
n = 6 | 0.55 | 87% | 0.78 | 85% | 0.78 | 85% |
n = 7 | 0.63 | 86% | 0.94 | 84% | 0.94 | 84% |
Back to search results | Back to search | Back to all product types