Type | Index number | Status |
---|---|---|
Centralised MEV and MVHR systems | 500759 | Normal |
Brand | Model name | Model qualifier |
ProAir | PA600HLI | |
System type | balanced whole-house mechanical ventilation with heat recovery | |
Duct type | rigid | |
Minimum duct size | 125 mm diameter or 204 x 60 rectangular or larger | |
Original manufacturer name | ProAir Heat Recovery and Ventilation Systems Ltd | |
Current manufacturer name | ProAir Heat Recovery and Ventilation Systems Ltd | |
Manufacturer address |
Tuam Road Head Office Unit 1 Polkeen Industrial Estate Castlegar H91 WYR8 Ireland |
|
Manufacturer phone | +353 91739442 | |
Manufacturer website | www.proair.ie | |
First year of manufacture | 2014 | |
Final year of manufacture | current | |
Summer bypass | no | |
Integrated to exhaust air heat pump | No | |
Entry updated | 08/04/2022 12:04 |
K+n wet rooms | SFP (W/l/s) [2009] | Efficiency (%) [2009] | SFP (W/l/s) [2012] | Efficiency (%) [2012] | SFP (W/l/s) [10] | Efficiency (%) [10] |
---|---|---|---|---|---|---|
n = 1 | 0.60 | 94% | 0.62 | 93% | 0.62 | 93% |
n = 2 | 0.56 | 93% | 0.67 | 92% | 0.67 | 92% |
n = 3 | 0.59 | 93% | 0.76 | 91% | 0.76 | 91% |
n = 4 | 0.69 | 92% | 0.92 | 91% | 0.92 | 91% |
n = 5 | 0.77 | 91% | 1.12 | 90% | 1.12 | 90% |
n = 6 | 0.89 | 91% | - | - | - | - |
n = 7 | 1.07 | 90% | - | - | - | - |
Back to search results | Back to search | Back to all product types